37
Word(s)
Function
Bit(s)
274
00
Special I/O Unit #0 Restart Flag
These flags will turn ON during restart processing.
01
Special I/O Unit #1 Restart Flag
These flags will not turn ON for Units on Slave
02
Special I/O Unit #2 Restart Flag
Racks.
03
Special I/O Unit #3 Restart Flag
04
Special I/O Unit #4 Restart Flag
05
Special I/O Unit #5 Restart Flag
06
Special I/O Unit #6 Restart Flag
07
Special I/O Unit #7 Restart Flag
08
Special I/O Unit #8 Restart Flag
09
Special I/O Unit #9 Restart Flag
10
Special I/O Unit #A Restart Flag
11
Special I/O Unit #B Restart Flag
12
Special I/O Unit #C Restart Flag
13
Special I/O Unit #D Restart Flag
14
Special I/O Unit #E Restart Flag
15
Special I/O Unit #F Restart Flag
275
00
PC Setup Error (DM 6600 to DM 6605)
01
PC Setup Error (DM 6613 to DM 6623)
02
PC Setup Error (DM 6645 to DM 6655)
03
Reserved by system (not accessible by user)
04
Changing RS-232C Setup Flag
05
Reserved by system (not accessible by user)
06 to 07
Reserved by system (not accessible by user)
08 to 15
Reserved by system (not accessible by user)
276
00 to 07
Minutes (00 to 59)
Indicates the current time in BCD.
08 to 15
Hours (00 to 23)
277 to 279
00 to 15
Used for keyboard mapping. See page 412.
280
00 to 15
Group-2 High-density I/O Unit Error Flags for Units 0 to F
(AR 0205 to AR 0214 also function as Error Flags for Units 0 to 9.)
281
00 to 15
Special I/O Unit Restart Bits for Units 0 to F
(Units 0 to 9 can also be restarted with Special I/O Unit Restart Bits AR 0100 to AR 0109.)
To restart a Special I/O Unit, either use for force-set/reset operation to turn the Restart Bit ON
and OFF, or turn OFF the power and then turn it ON again.
Follow the same procedure as above for starting PC Link Units.
282
00 to 15
Special I/O Unit Error Flags for Units 0 to F
(AR 0000 to AR 0009 also function as Error Flags for Units 0 to 9.)
283 to 286
00 to 15
Communications Board monitoring area
287 to 288
00 to 15
Communications Board interrupt data area
289
00 to 07
Communications Board general monitoring area
08
Communications Board Port A Instruction Execution Flag
09 to 10
Used by Communications Board Port A instructions
11
Communications Board Port A Instruction Abort Bit
12
Communications Board Port B Instruction Execution Flag
13 to 14
Used by Communications Board Port B instructions
15
Communications Board Port B Instruction Abort Bit
290 to 293
00 to 15
Macro Area inputs.
294 to 297
00 to 15
Macro Area outputs.
298 to 299
00 to 15
Reserved by system (not accessible by user)
SR (Special Relay) Area
Section 3-4