Omron C200HX 用户手册

下载
页码 564
277
5-22-3 LOGICAL OR – ORW(35)
I1: Input 1
IR, SR, AR, DM, HR, TC, LR, #
I2: Input 2
IR, SR, AR, DM, HR, TC, LR, #
Ladder Symbols
Operand Data Areas
R: Result word
IR, SR, AR, DM, HR, LR
ORW(35)
I1
I2
R
@ORW(35)
I1
I2
R
Description
When the execution condition is OFF, ORW(35) is not executed. When the
execution condition is ON, ORW(35) logically OR’s the contents of I1 and I2 bit-
by-bit and places the result in R.
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
15
00
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
0
1
1
1
0
1
1
1
0
1
1
1
0
1
15
00
15
00
I1
I2
R
Flags
ER:
Indirectly addressed DM word is non-existent. (Content of 
DM word is
not BCD, or the DM area boundary has been exceeded.)
EQ:
ON when the result is 0.
N:
ON when bit 15 of R is set to 1.
Example
Logic Instructions