ASUS DSEB-D16/SAS 用户手册

下载
页码 200
5-22
Chapter 5: RAID configuration
5.2.5 
Rebuilding failed drives
You can manually rebuild failed hard disk drives using the Rebuild command in the 
Management Menu.
To rebuild a failed hard disk drive:
1.  From the Management Menu, highlight Rebuild, then press <Enter>.
2.  The PHYSICAL DRIVES SELECTION MENU displays the available drives 
connected to the SATA ports. Select the drive you want to rebuild, then press 
<SpaceBar>.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
Management Menu
Configure
 
Initialize 
Objects 
Rebuild
 
Check Consistency
Rebuild PD(s)
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP
Management Menu
Configure
 
Initialize 
Objects 
Rebuild
 
Check Consistency
Port # 1 DISK   77247MB   HDS728080PLA380   PF20A60A
REBUILD - PHYSICAL DRIVES SELECTION MENU
PORT #
ONLIN A00-00
FAIL  A00-01
0
1