Symmetricom 1100 用户手册

下载
页码 224
097-58001-02 Revision G – April 2008
TimeProvider User’s Guide
33
Chapter 1 Overview of the TimeProvider
System Power
Output Module
The Output module provides the output connectors for the TimeProvider. Like the 
Input module, each Output module uses one of a variety of connectors that match 
the wiring system at the installation site. 
describes the Output Modules available for the TimeProvider and the Expansion 
Panel.
Expansion Panel
The Expansion Panel provides up to 32 additional outputs that the TimeProvider 
can generate. Se
for more information.
TimeProvider Interface Unit
The TimeProvider Interface Unit (TPIU) provides power, communication, and a 
composite timing reference signal between the antenna and the TimeProvider main 
shelf. The TPIU is an external, stand-alone rack mounted assembly included in 
Antenna Kits 990-58545-01 and 990-58545-02. The TPIU can be used only with 
IMC card 090-58031-01. During antenna installation, you can use the LEDs on the 
TPIU to detail the status of the received power and antenna communication. See 
, on page 71 for more information.
System Power
The TimeProvider main shelf has redundant –48v DC inputs. The inputs are diode 
or’d; in the event that one supply fails, the other takes over. The –48v returns are 
isolated from the chassis and circuit grounds. A 5 A fuse on the IOC protects the 
TimeProvider; the shelf is protected from damage in case the connections are 
reversed.
The power supply range is from –36 to –72 V DC. The power requirements vary 
according to the type of IOC installed; 
 lists the power requirements.
The procedure for installing power is described in 
Table 1-1.  Typical Power Consumption
IOC Type
Max Power (W) 
per IOC
Typical Power (W) 
per IOC
Crystal
40
30
Rubidium
60
40
(70 with two Rb IOCs)