Q-Logic 8100 SERIES 用户手册

下载
页码 348
7–Configuring FCoE in a Windows Environment
Boot from SAN
FE0254601-00 A
7-17
Confirm the following:
The adapter port has exclusive access to this LUN.
The LUN host type matches the operating system that is to be installed on 
this LUN.
Each server must have its own dedicated boot LUN. Two servers cannot share the 
same boot LUN.
Boot-from-SAN Configuration
Boot-from-SAN requires the configuration of the QLogic 8100 Series Adapter, the 
FCoE switch, and the storage array. How you connect these SAN components is 
determined by the level of redundancy you require. There are minor differences 
when configuring the QLogic 8100 Series Adapter for boot-from-SAN between 
servers that support BIOS and those that support UEFI.
The following subsections describe how to configure the QLogic 8100 Series 
Adapter and SAN components for boot-from-SAN. The following summarizes the 
configuration process:
1.
Set the boot order to disable boot-from-local-disk, or disconnect the internal 
hard drives.
2.
Configure a single path to the storage array when installing Microsoft 
Windows. For multiple adapter port configurations (for redundancy), connect 
only one adapter port to the SAN during installation. The same guidance 
applies to the storage controller ports.
3.
Enable the adapter port BIOS.
4.
Specify a boot LUN using the QLogic CNA Fast!UTIL BIOS configuration 
utility.
5.
Boot from the optical drive. Install media/PXE boot, and then install the 
operating system.
6.
During the operating system installation process, select the boot LUN as the 
device on which to install the operating system.
7.
Enable multipath (MPIO) configuration on the server after installing the 
operating system.
Boot-from-SAN Topologies
One of the benefits of SAN adoption, and in turn, boot-from-SAN, is high 
availability, which is not easily achieved in a local boot scenario. Before configuring 
boot-from-SAN, you must understand and finalize the level of fault tolerance and 
high availability required for boot-from-SAN installations. The following sections 
describe two boot-from-SAN topologies: single-path configuration (least fault 
tolerant) and multipath configuration (most fault tolerant).