Q-Logic 8100 SERIES 用户手册

下载
页码 348
B–Cisco Nexus 5000 Series Switch Configuration
Verify that the Adapter Is Logged into the Switch
FE0254601-00 A
B-5
Verify that the Adapter Is Logged into the Switch
To verify that the switch has been properly configured and that the adapter has 
logged into the switch:
1.
List the devices that have logged into the switch, and compare the device 
WWN with the information from the QLogic adapter port by entering the 
show flogi database command. In the example, vfc 19 is logged into 
the switch and visible in the switch name server database.
nexusmv1(config-if)# show flogi database
--------------------------------------------------------------------------------
INTERFACE        VSAN    FCID           PORT NAME               NODE NAME
--------------------------------------------------------------------------------
fc2/1            1     0xc60000  20:04:00:20:c2:08:57:95 10:00:00:20:c2:08:57:95
fc2/2            1     0xc60001  20:03:00:20:c2:08:57:95 10:00:00:20:c2:08:57:95
fc2/3            1     0xc60004  20:02:00:20:c2:08:57:95 10:00:00:20:c2:08:57:95
fc2/4            1     0xc60002  20:01:00:20:c2:08:57:95 10:00:00:20:c2:08:57:95
fc3/1            1     0xc60006  20:04:00:20:c2:04:50:24 10:00:00:20:c2:04:50:24
fc3/3            1     0xc60005  20:02:00:20:c2:04:50:24 10:00:00:20:c2:04:50:24
fc3/5            1     0xc60007  20:01:00:20:c2:04:50:24 10:00:00:20:c2:04:50:24
fc3/7            1     0xc60008  20:03:00:20:c2:04:50:24 10:00:00:20:c2:04:50:24
vfc19            1     0xc6001c  10:00:00:00:c9:9c:c2:ed 20:00:00:00:c9:9c:c2:ed
Total number of flogi = 9.
2.
Verify the detailed properties of the virtual Fibre Channel interface.
show interface vfc 19
3.
Configure zoning on the switch, as needed. For information about zoning the 
switch, refer to the Cisco switch documentation.
4.
Save the current switch configuration so that the configuration is persistent 
across switch reboots by issuing the following command:
copy running-config startup-config