Checking the Stock Registration 
If you Calibrate Stock, there is no need to calibrate the sensor. 
1. 
Load the supply for non-peel mode as shown below. 
2. 
Select Stock Registration from the Printer Diagnostics window.  
3. 
Select the sensor to calibrate (either Black Mark or On-Demand).  The black mark sensor is 
used with black mark supplies (supplies with rectangular marks on the back side of the liner 
or on the supply).  The on-demand sensor is for peeled supplies.  
4. 
For black mark supplies longer than 4.0 inches, make sure supplies are loaded with a black 
mark slightly below the sensor as shown below.  This feeds the least amount of labels during 
the calibration process.   
B l a ck   m ar k  on   s u p p l y  s l i gh t l y 
b e l ow   se n s or w it h   e n o u g h   l a b el  
t o   f e e d  t hr o ug h   p r i n t er .  
B l a ck   M ar k   Se n s o r  
5. 
Close the supply cover, then touch Calibrate Sensor to calibrate the black mark sensor. 
The printer feeds supply until it detects a black mark to calibrate the sensor.  When the 
calibration is successful, a message appears:  “Black Mark stock sensor calibration 
successful.”  Touch OK
Using Printer Diagnostics  6-5