Avery 256 用户手册

下载
页码 58
47
C
ONTENTS
5.1 M
AINTENANCE
 
AND
 
CLEANING
ALS
20x 
256
GB
5.1.1
Replacing fuses
This section counts only for ALS 20X. The fu-
ses at the ALS 256 cannot be replaced.
WARNING!
The machine operates using mains voltage! 
Touching live electrical parts may expose 
you to hazardous electrical currents and 
may lead to burns.
£
Make sure that the machine is switched 
off and the power cable is unplugged 
before removing the fuse insert. 
CAUTION!
Risk of fire, if a wrong fuse type is inserted.
£
Only replace fuses with the type and 
rating specified in this manual.
The F1 and F2 fuses protect the primary side of 
the transformer. At any given time, only one of 
the two fuses is active. Which fuse is active 
depends on the switch setting of the voltage 
selector switch.
[49] Relation between the switch setting of the voltage selector 
switch and the active fuse.
The CPU board and sensors are protected by a 
separate fuse in the switching power supply that 
must/may never be replaced.
If either of the two fuses is not working properly, only 
the drive motors are affected; the display and sensors 
continue to operate as normal.
Tool: Screwdriver
£
Turn off the unit. Unplug the power cable.
£
Rotate the fuse holder a few degrees anticlockwise.
– The fuse holder pops up.
£
Take the fuse out of the fuse holder.
£
Replace defective fuse.
£
Replace the fuse holder and rotate it clockwise, 
while applying light pressure, until the slot is 
vertically positioned.
Required fuse type:
– T5AH 250 V
[50] Fuse holder (A) of the ALS  20x.
Active fuse
Mains voltage
Switch setting
F1
230 V
230
F2
110 V
115
A
5
A
F T E R
 
O P E R A T I O N
5.1