Specifications and Product Data
Specifications and Product Data 6-1
MN715
Specifications:
Horsepower
1-50 HP @ 230VAC
1-800 HP @ 460VAC
1-600 HP @ 575VAC
Input Frequency
50/60Hz 
±
 5%
Output Voltage
0 to Maximum Input VAC
Output Current
See Ratings Table
Output Frequency
0 to 120Hz or 0 to 400Hz (jumper selectable)–
Service Factor
1.0
Duty
Continuous
Overload Capacity
Constant Torque Mode:
170-200% for 3 secs
150% for 60 secs
Variable Torque Mode: 
115% for 60 secs
Frequency Setting
Keypad, 0-5VDC, 0-10VDC, 4-20mA
Frequency Setting Potentiometer
5k
W
 or 10k
W
, 1/2 Watt
Rated Storage Temperature:
– 30
°
C to +65
°
C
Power Loss Ridethrough
15ms minimum at full load, 200 ms at idle
Power Factor (Displacement)
0.95% minimum
Efficiency
95% minimum at full load and speed
Operating Conditions:
Voltage Range:    230 VAC Models
460 VAC Models
575 VAC Models
180-264 VAC 3
f
 60Hz/180-230 VAC 3
f
 50Hz
342-528 VAC 3
f
 60Hz/340-457 VAC 3
f
 50Hz
495-660 VAC 3
f
 60Hz
Input Line Impedance:
3% Minimum Required (A, B, C, D, E Sizes)
1% (B2, C2, D2, F, G, G2, G+, H Sizes)
Ambient Operating Temperature:
0 to +40
°
C
Derate Output 2% per 
°
C
over 40
°
C to 55
°
C (130
°
F) Maximum
Enclosure:
NEMA 1:
E, EO and ER (suffix) Models
NEMA 4X: 
W (suffix) Models
Protected Chassis
MO and MR (suffix) Models
Humidity:
NEMA 1 & protected: 
To 90% RH non-condensing
NEMA 4X: 
To 100% RH condensing
Altitude:
Sea level to 3300 feet (1000 meters)
Derate 2% per 1000 feet (303 meters) above 3300 feet
Shock:
1G
Vibration:
0.5G at 10Hz to 60Hz
Keypad Display:
Display
Backlit LCD Alphanumeric 
2 Lines x 16 Characters
Keys
Membrane keypad with tactile response
Functions
Output status monitoring
Digital speed control
Parameter setting and display
Fault log display
Motor run and jog
Local/Remote
LED Indicators
Forward run command
Reverse run command
Stop command
Jog active
Remote Mount
100 feet Maximum from control