Baldor Baldor 用户手册

下载
页码 70
Appendix B
Parameter Values
Applications B-1
MN850
Version 5MC  (4/2/01)             
  Read Only Parameter Values
Title
P#
Parameter
Adjustable Range
Factory
User Setting
Parameter
P0
Dummy Parameter
0–255
0
P1
Station Number
1–99
1
P2
Country
1–255
44 (England)
P3
Software Type
Factory Set
Read Only
P4
Software Version
Factory Set
Read Only
Password
P5
Password Value
0–255
0
Advanced
P6
Firing Mode
0–3
0
Basic
P7
Protection Mode
0–192
192 (Full + Optimize)
Parameters
P8
Status 1
0–255
1 (bit 00000001)
P9
Status 2
0–99
0 (bit 00000000)
P10
Status 3
0–255
0 (bit 0000000)
Basic
P11
Start Pedestal
10–60%
20 (% of line volts)
P12
Start Time
1–255 seconds
5 (seconds)
Advanced
P13
Kick Pedestal
60–90%
75 (% of Line)
P14
Kick Time
10–40 cycles
25 Cycles
P15
Dwell Time
1–255 seconds
5 seconds
Basic
P16
Stop Pedestal
10–60%
10 (% of Line)
P17
Stop Time
0–255 seconds
0 seconds
Auto Features
P18
Auto Config.
0–255
6 (bit 00000110)
Advanced
P19
Optimise Rate
4–30
5 (for unstable load)
Parameters
P20
Reference PF (Power Factor)
0–147 degrees
146.7626 degrees
P21
Present PF  (Power Factor)
0–147 degrees
146.7626 degrees
P22
Delay Angle (SCR OFF time)
0–147 degrees
146.7626 degrees
P23
Maximum Optimizing Delay
17–147 degrees
57.55396 degrees
P24
Rated Current (High Byte –Hundreds)
Factory Set
Factory Set
P25
Rated Current (Low Byte – Units)
Factory Set
Factory Set
P26
Running Current Amps
0–255 Amps
0 Amps
P27
Peak Start Current (measured at last start)
0–255 Amps
0 Amps
Advanced Current
P28
Low Current Level (undercurrent trip)
100–800% of running
Amps (P24 & P25)
9.375% of running
Amps
P29
Low Current Time (delay before trip)
5–255 seconds
50 seconds
P30
Current Limit Level (scaling = 0.03125)
1–7.96875 (x 
I
e) Amps
350% of running
Amps
P31
Current Limit Time (delay before trip)
5–255 seconds
30 seconds
P32
Shearpin Level (undercurrent trip)
1–5 (x 
I
e) Amps
3.125 x 
I
e Amps
P33
Shearpin Time (delay before trip)
5–255 cycles
100 cycles
P34
Overload Level  (SCR protection)
0.59–2 (x 
I
e) Amps
1.09375 x 
I
e Amps
 
P35
Overload Delay (delay before trip)
10–140
140
Note: (x 
I
e) means “Times the rated current of the control (P24 and P25 values).”