HGST TRAVELSTAR 80GN 30GB ATA5 08K0910 用户手册

产品代码
08K0910
下载
页码 214
Travelstar 80GN Hard Disk Drive  Specification
page 92
4.  For the Read Long command:
a.  The device sets BSY = 1 and prepares for data transfer.
b.  When the sector of data is available for transfer to the host, the device sets BSY = 0 and DRQ=1 and 
interrupts the host.
c.  In response to the interrupt, the host reads the Status Register.
d.  The device clears the interrupt in response to the Status Register being read.
e.  The host reads the sector of data including ECC bytes via the Data Register.
f.  The device sets DRQ = 0 after the sector has been transferred to the host.
The Read Multiple command transfers one block of data for each interrupt. The other commands transfer one sec-
tor of data for each interrupt.
Note that the status data for a sector of data is available in the Status Register before the sector is transferred to the 
host.
If the device detects an invalid parameter, then it will abort the command by setting BSY = 0, ERR = 1, ABT = 1, 
and interrupting the host.
If an error occurs, the device will set BSY = 0, ERR = 1, and DRQ = 1. The device will then store the error status 
in the Error Register and interrupt the host. The registers will contain the location of the sector in error. The error 
location will be reported using CHS mode or LBA mode. The mode is decided by the mode select bit (bit 6) of the 
Device/Head register upon issuing the command.
If an Uncorrectable Data Error (UNC = 1) occurs, the defective data will be transferred from the media to the sector 
buffer and will be available for transfer to the host at the host's option. In case of a Read Multiple command, the 
host should complete transfer of the block which includes the error from the sector buffer and terminate whatever 
type of error that occurred.
All data transfers to the host through the Data Register are 16 bits. The ECC bytes are an exception having only 
8 bits.
12.2  Data Out Commands
The following are Data Out commands:
Device Configuration SET
Format  Track
Security Disable Password
Security Erase Unit
Security Set Password
Security Unlock
Set Max SET PASSWORD
Set Max UNLOCK
S.M.A.R.T. Write log sector
Write Buffer
Write Long
Write Multiple
Write Miltiple EXT
Write Sector(s)