6.6.1. Input 
Power 
 
The Enfora Enabler II-G A-GPS module uses a single voltage source of VCC=+3.3V to 4.5V.  
(The exact values of the uplink currents are shown in Tables5.3.1 GSM Operating Power 
and 5.3.2 GPRS Operating Power).  The V
CC
 lines (pins 1 to 6) should be connected on the 
application board.   
 
 
The uplink burst will cause strong ripple on the voltage 
lines and should be effectively filtered.  It is recommended 
that 1000 to 2000 μF of capacitance be placed as close to 
the modem I/O connector as possible. 
 
It should be noted that the input voltage level should not 
drop below the minimum voltage rating under any 
circumstances, especially during the uplink burst period.
 
 