SEAL 44Ultra Laminator 用户手册

下载
页码 49
 
 
Disassembly / Reassembly Procedures 
23 
 
4-6 Photoelectric 
Cells 
 
Note: to perform the following adjustments, it is necessary to remove both plastic side covers first. See 
section 4.1: Disassembly / Reassembly plastic side covers. 
 
Necessary tools: small flat head screwdriver, Allen key 3mm 
Necessary materials: two tie-wraps (2.5 – 3 mm wide), per Photoelectric Cell. 
Approximate time: 10 minutes. 
 
Note: perform the Photoelectric Cells Adjustment procedure once the Photoelectric 
Cell(s) have been replaced. 
 
The Photoelectric Cells are fitted on the arms of the upper roller. Viewed from the front-side of the 
machine, the transmitter is mounted at the left-hand side and the reciever is mounted at the right-hand 
side of the machine. 
The difference between the transmitter and the receiver is shown below. 
 
 
 
 
Disassembly reciever or transmitter. 
 
1.  With the aid of a small screwdriver, remove the springclip (see figure 18). 
 
 
 
 
 
 
 
 
 
 
 
2.  Cut and discard the two tie-wraps. 
3.  Pull the connector out of the Photoelectric Cell (see figure 19). 
 
fig. 17 
fig. 18 
fig. 19