SEAL 44Ultra Laminator 用户手册
Disassembly / Reassembly Procedures
23
4-6 Photoelectric
Cells
Note: to perform the following adjustments, it is necessary to remove both plastic side covers first. See
section 4.1: Disassembly / Reassembly plastic side covers.
Necessary tools: small flat head screwdriver, Allen key 3mm
Necessary materials: two tie-wraps (2.5 – 3 mm wide), per Photoelectric Cell.
Approximate time: 10 minutes.
Note: perform the Photoelectric Cells Adjustment procedure once the Photoelectric
Cell(s) have been replaced.
Cell(s) have been replaced.
The Photoelectric Cells are fitted on the arms of the upper roller. Viewed from the front-side of the
machine, the transmitter is mounted at the left-hand side and the reciever is mounted at the right-hand
side of the machine.
The difference between the transmitter and the receiver is shown below.
Disassembly reciever or transmitter.
1. With the aid of a small screwdriver, remove the springclip (see figure 18).
2. Cut and discard the two tie-wraps.
3. Pull the connector out of the Photoelectric Cell (see figure 19).
fig. 17
fig. 18
fig. 19