Acer DT85 用户手册

下载
页码 208
CHAPTER 4: Troubleshooting
146
No-beep error messages
Invalid System Configuration Data
• Test or replace the BIOS ROM.
• Test or replace the system board.
I/O device IRQ conflict
• Run “Load Setup Defaults” using the BIOS Setup Utility, then 
reboot the notebook.
• Test or replace the CMOS battery, run the BIOS Setup Utility 
to reconfigure system time, then reboot the system.
• Test or replace the system board.
Operating system not found
• Run the BIOS Setup Utility and see if fixed disk and drive A: 
are properly identified.
• Test or replace the diskette drive
• Test or replace the hard disk drive
• Test or replace the system board
No-beep Error Messages
FRU/Action in Sequence
No beep, power-on indicator turns off and 
LCD is blank.
• Test the power source (battery pack and power adapter). 
• Make sure that every connector is connected tightly and 
correctly. 
• Reconnect the SO-DIMM.
• Test or replace the LED board.
• Test or replace the system board.
No beep, power-on indicator turns on and 
LCD is blank.
• Test the power source (battery pack and power adapter). 
• Reconnect the LCD connector
• Check the hard disk drive.
• Check the LCD inverter ID.
• Check the LCD cable.
• Test or replace the LCD inverter.
• Test or replace the LCD.
• Test or replace the system board.
No beep, power-on indicator turns on and 
LCD is blank. But you can see POST on 
an external CRT. 
• Reconnect the LCD connectors.
• Check the LCD inverter ID.
• Check the LCD cable.
• Test or replace the LCD inverter.
• Test or replace the LCD.
• Test or replace the system board.
No beep, power-on indicator turns on and 
a blinking cursor shown on LCD during 
POST.
• Make sure that every connector is connected tightly and 
correctly.
• Test or replace the system board.
No beep during POST but system runs 
correctly.
• Test or replace the speaker.
• Test or replace the system board.
Error Messages
FRU/Action Sequence