Acer 7730 用户手册

下载
页码 254
138
Chapter 4: Troubleshooting
Numeric keypad
External keyboard
If any of these devices do not work, reconnect the cable connector and repeat the failing 
operation.
Testing the memory
Memory errors can stop your programs, show error messages on the screen, or hang the system.
To test the memory:
1
Boot from the diagnostics diskette and start the diagnostics program.
2
Run the Memory Test and see if the test completes successfully.
3
Press F2 in the test items.
4
Follow the instructions in the message window.
Note:
 Make sure that each memory card is fully installed into the 
connector. A loose connection can cause an error.
Testing the power system
To test for a power problem:
1
Turn on the notebook using each of the following power sources:
Remove the battery pack, connect the power adapter, then make sure that 
the notebook turns on using AC power.
Disconnect the power adapter, install a charged battery pack, then make sure 
that power is supplied by the battery pack.
If you suspect a power problem, complete the appropriate power supply check:
Check the power adapter
Unplug the power adapter cable from the notebook and measure the output voltage at the 
power adapter cable plug. See the following figure.
1
If the voltage is not correct, replace the power adapter.
2
If the voltage is within the range, do the following:
Replace the system board.
If the problem is not corrected, see 
.
If the voltage is not correct, go to 
.
Note:
 An audible noise from the power adapter does not always indicate 
a defect.
Pin 1: +19 to +20.5V
Pin 2: 0V, Ground