Acer 7730 用户手册

下载
页码 254
150
Chapter 4: Troubleshooting
Devices
The system doesn't hibernate and emits 
four short beeps every minute.
• Press Fn+
and see if the notebook enters hibernation 
mode.
• Test or replace the touchpad.
• Test or replace the keyboard.
• Check the hard disk connection to the system board.
• Test or replace the hard disk drive.
• Test or replace the system board.
The notebook doesn’t enter standby 
mode after closing the LCD.
<Athena: Why are they looking at a spec?>
 See 
.
• Test or replace the system board.
The system doesn't resume from 
hibernation mode.
<Athena: Why are they looking at a spec?>
 See 
.
• Check the hard disk connection to the system board.
• Test or replace the hard disk drive.
• Test or replace the system board.
The system doesn't resume from standby 
mode after opening the LCD.
<Athena: Why are they looking at a spec?>
 See 
.
• Test or replace the system board.
The battery fuel gauge in Windows 
doesn’t go higher than 90%. 
• Remove the battery pack and let it cool for two hours.
• Refresh the battery (use only battery power until the 
notebook turns off, then charge the battery).
• Test or replace the battery pack.
• Test or replace the system board.
The system hangs intermittently.
• Reconnect the hard disk drive and optical drive.
• Check the hard disk connection to the system board.
• Test or replace the system board.
Symptom / Error
Action in Sequence
System configuration does not match the 
installed devices. 
• Run “Load Setup Defaults” using the BIOS Setup 
Utility, then reboot the notebook.
• Reconnect the hard disk drive and optical drive.
The external display does not work 
correctly.
• Press Fn+F5 repeatedly to switch between LCD, 
external display, and both displays.
• Test or replace the system board.
USB does not work correctly.
• Test or replace the ExpressCard assembly. See 
• Test or replace the system board. 
Printer problems.
• Run the printer self-test.
• Reinstall the printer driver.
• Test or replace the printer cable.
• Test or replace the printer.
• Test or replace the system board.
Serial or parallel port device problems.
• Reinstall the device driver.
• Test or replace the device cable.
• Test or replace the device.
• Test or replace the system board.
Symptom / Error
Action in Sequence