Loopback Tests
Alarms
Display Alarms
Use the alarms command to display the active alarms. Each alarm is related to a 
particular address and has a severity category (major, minor, critical, alert). The 
report can be filtered by port address and/or severity. 
Syntax:
alarms
 [slot|slot:port|slot:port:channel] [category] 
[severity]
 
> alarms
 Time      Date    Severity Description
  07:35:45 01/04/2002 Major    Test Major Alarm
  07:35:21 01/04/2002 Minor    Test Minor Alarm
  07:34:57 01/04/2002 Critical Test Critical Alarm
  00:00:20 01/01/2002 Major    6:1-TSR Ethernet Link Down
  00:00:05 01/01/2002 Major    A:2-DS1 Loss Of Signal
  00:00:05 01/01/2002 Major    A:1-DS1 Loss Of Signal
Total=6
Category = bri|ds1|env|equipment|fxo|fxs|rtr|v35
Severity = alert|critical|info|major|minor
           
Clear Alarm
Once an alarm is identified then the process of clearing it can begin.
Silence Alarm, if necessary (Alarm Cut Off CLI command: aco)
Check Connection
Check Cable, replace if necessary
Check hardware and replace if necessary
Call Customer Service