Toshiba MDB-100 用户手册

下载
页码 38
 
 30 
Trip Data Codes 
 
Display Data 
Trip 
Type 
nErr 
0000 No 
trip 
OC1 
0001 
Overcurrent during acceleration 
OC2 
0002 
Overcurrent during deceleration 
OC3 
0003 
Overcurrent during constant-speed run 
OCL 
0004 
Load-end short circuit trip during start-up 
OCA 
0005 
Phase short circuit 
 
0006 
reserved 
 
0007 
reserved 
EPH1 
0008 reserved 
EPH0 
0009 
Loss of output phase 
OP1 
000A 
Overvoltage during acceleration 
OP2 
000B 
Overvoltage during deceleration 
OP3 
000C 
Overvoltage during constant-speed run 
OL1 
000D 
Inverter overload trip 
OL2 
000E 
Motor overload trip 
OLr 
000F DBR 
overload 
OH 
0010 Overheat 
trip 
0011 Emergency 
stop 
EEP1 
0012 
EEPROM fault: write error 
 
0013 
reserved 
 
0014 
reserved 
Err2 
0015 RAM 
fault 
Err3 
0016 ROM 
fault 
Err4 
0017 CPU 
fault 
Err5 
0018 
Communication interruption error 
 
0019~0024  reserved 
OCr 
0025 
Dynamic braking resistor trip 
 
0026~0027  reserved 
Etn 
0028 Auto-tuning 
error 
EtYP 
0029 
Inverter typeform error