Toshiba MDB-100 用户手册
30
Trip Data Codes
Display Data
Trip
Type
nErr
0000 No
trip
OC1
0001
Overcurrent during acceleration
OC2
0002
Overcurrent during deceleration
OC3
0003
Overcurrent during constant-speed run
OCL
0004
Load-end short circuit trip during start-up
OCA
0005
Phase short circuit
0006
reserved
0007
reserved
EPH1
0008 reserved
EPH0
0009
Loss of output phase
OP1
000A
Overvoltage during acceleration
OP2
000B
Overvoltage during deceleration
OP3
000C
Overvoltage during constant-speed run
OL1
000D
Inverter overload trip
OL2
000E
Motor overload trip
OLr
000F DBR
overload
OH
0010 Overheat
trip
E
0011 Emergency
stop
EEP1
0012
EEPROM fault: write error
0013
reserved
0014
reserved
Err2
0015 RAM
fault
Err3
0016 ROM
fault
Err4
0017 CPU
fault
Err5
0018
Communication interruption error
0019~0024 reserved
OCr
0025
Dynamic braking resistor trip
0026~0027 reserved
Etn
0028 Auto-tuning
error
EtYP
0029
Inverter typeform error