Recommended Hydraulic Schematic for Shared Equipment System
Plumb the solar feed and return lines between the filter and the heater. Install a three-port valve
at the feed line. Use a solar valve (model SOL-2T), to allow automatic draining of the panels.
at the feed line. Use a solar valve (model SOL-2T), to allow automatic draining of the panels.
A solar booster pump should be used when the distance to the panels exceed 200 ft., or the
panels are elevated higher than 25 ft.
panels are elevated higher than 25 ft.
Glazed solar panels require a drain valve (model HW-5B) to allow draining of the panels. This
prevents damage from overheating water. Install a drain valve at the solar feed line and connect
to the pool fill line.
prevents damage from overheating water. Install a drain valve at the solar feed line and connect
to the pool fill line.
SCG systems only: IntelliChlor cell with check valve between the heater and valves. Refer to
IntelliChlor User’s Guide (P/N 520589) page 4 for plumbing requirements.
IntelliChlor User’s Guide (P/N 520589) page 4 for plumbing requirements.
Equipment Location