Vanguard Managed Solutions 6500 PLUS 用户手册

下载
页码 102
B-2 
Specifications
Power 
Requirements
Environmental 
Limits
• All enclosures, 6500 CPU, 6500
PLUS
 processor, 6500 I/O cards: 0° C to 50° C 
(32° F to 122° F)
• 6500 NSO card: 0° C to 45° C (32° F to 113° F)
• Storage Temperature: –40° C to 70° C (–40° F to 158° F)
• Relative Humidity: 5% to 90% (noncondensing)
Modulus 21
Height: 14.0 in. (35.6 cm)
Width:17.8 in. (45.2 cm)
Depth: 20.75 in. (52.7 cm)
Weight (Empty): 48 lb (21.8 kg)
Max Number of 6500 Series Product 
Cards: 9
Unit (continued)
Dimensions
Standalone Enclosure
100-240 VAC nominal, 47 to 63 Hz 
Modulus 8
100-120 VAC, 8.0 A, 50 to 60 Hz
220-240 VAC, 6.0A, 50 to 60 Hz
Modulus 9
100-120 VAC, 5.0A, 50 to 60 Hz
220-240 VAC, 3.0A, 50 to 60 Hz
Modulus 18 and Modulus 21
100-120 VAC, 10.0A maximum, 50 to 
60 Hz
220-240 VAC, 6.0A maximum, 50 to 
60 Hz
Modulus 18, -48 VDC Power 
Supply Module
-48 to -60 VDC, 10.0A maximum
Modulus 21, -48 VDC Power 
Supply Module
-48 to -60 VDC, 15.0A maximum
Power Rating for 6500
PLUS
 
Processor Card with TRIM Card
18.5