6.4.4 Fan(s) Not Working / Overheating 
This equipment has forced air cooling and must not be operated unless 
all cooling fans are working. In the event of overheating problems, refer 
to table. 
 
Note: Failure to ensure a free air flow around the unit may cause 
overheating. 
6.4.5 Alarm LED lit / Alarm condition 
The alarm LED on front and rear will light when a critical alarm occurs. 
The following table describes the different alarm conditions and what 
might be the cause of these alarms. 
Step 
Action 
If the result of action is Yes...      If the result of action is 
No... 
Check Fan 
Rotation. 
Inspect the fans 
located at the 
sides of the unit. 
Are the fans 
rotating?       
Check that the Video Gateway 
has been installed with sufficient 
space allowed enclosure for air 
flow. If the air is too hot,        
additional cooling may be 
required.                                    
Possible break in the dc 
supply from the PSU module 
to the suspect fan(s). Call a 
Service Engineer.