PioneerPOS G24-LC 用户手册

下载
页码 444
Chapter 3:  AT Commands Reference
 April 15, 2008
G24-L AT Commands Reference Manual
3-47
+CAMM, Accumulated Call Meter Maximum
This command sets the Advice of Charge accumulated call meter maximum value in the SIM file, 
EFACMmax. ACMmax contains the maximum number of home units the subscriber is able to 
consume. When the ACM (
) reaches 
ACMmax, additional calls (mobile-originated and mobile-terminated calls that incur charges) are 
prohibited, except for emergency calls. Refer to GSM 02.24.
The following table shows the +CAMM parameters.
Example
AT+CAMM=?
OK
AT+CAMM="FFFFFF","2222"
OK
AT+CAMM?
+CAMM: "FFFFFF"
OK
Command Type
Syntax
Response/Action
Remarks
Set
+CAMM=[<acm
max>,<passwd>]
OK
+CME ERROR: <err>
The Set command sets the 
accumulated call meter maximum 
value. SIM PIN2 is required. The value 
that is set remains after a power cycle.
Note:
This command is activated if 
Advice of Charge is supported 
by the network.
Read
+CAMM?
+CAMM: <acmmax>
+CME ERROR: <err>
The Read command displays the 
current value of ACMmax.
Test
+CAMM=?
OK
The Test command indicates whether 
the +CAMM command is functioning.
Table 3-23: +CAMM Parameters
<Parameter>
Description
<acmmax>
Accumulated call meter maximum value (similar to CCM; 
)
<ccm>
String type; three bytes of the current call meter value in hexadecimal format (for 
example, 00001E indicates a decimal value of 30). Value is given in home units; bytes 
are similarly coded as the ACMmax value in the SIM.
Range is from 00001 to FFFFFF.
0
Disables ACMmax (default)
<passwd>
SIM PIN2 password
Maximum string length is 8 characters. If this value is exceeded, the command 
terminates in an error. If PIN2 is incorrect, "+CME ERROR: incorrect password" is 