PioneerPOS G24-LC 用户手册

下载
页码 444
Hardware Information
3-130
 G24-L AT Commands Reference Manual
April 15, 2008
OK
+MBC, Battery Charger
This command allows the battery charger to be managed (start, stop or automatic manage) and get 
indication for the battery level (solicited or unsolicited reports).
The Battery is external to the G24-L and connected via the 70 pin connector.
The values of the battery are: 3.2V-4.2V divided to 5 battery levels.
Notes:
• When the battery level is below the minimum, the G24-L will not power up untill the 
pre-chargelevel reaches the minimum level for activation.
• The G24-L will manage the charging process and algorithm when charging is enabled.
• The unsolicited reports will appear in the following cases (in case <Ind=1>):
1.
Each time the level of the battery changes.
2.
Inside the limits (3.2 and 4.2).
3.
Charger connected/disconnected.
• The unsolicited report will appear even if the charger cable is not connected (only in 
case of <Ind=1>).
• ERRORS: Trying to start a charging process without a battery, error message of: NO 
BATTERY DETECTION will be received, for any other problems the following will 
be received: ERROR IN CHARGING PROCESS.
Command 
Type
Syntax
Response/Action
Remarks
Set
AT+MBC=<Mode>,<
Ind >
OK 
or:
+CME ERROR: <err>
The Set command sets the different 
mode (start, stop or automatic) and 
sets the report to be solicited or 
unsolicited.
Read
AT+MBC?
+MBC: 
<Status>,<Batterylevel
>,<Mode>,<Ind>
OK
The Read command returns the current 
status, battery level, mode and 
indication.
Test
AT+MBC=?
+MBC: (List of 
supported Mode),(List 
of supported 
Indication)
OK
The Test command returns the list of 
supported modes and indications.