PioneerPOS G24-LC 用户手册

下载
页码 444
Chapter 3:  AT Commands Reference
 April 15, 2008
G24-L AT Commands Reference Manual
3-143
ATS97, Antenna Diagnostic
This command indicates whether an antenna is physically connected to the G24-L RF connector. 
This information is also provided by a dedicated hardware signal, which is outputted on pin 41 
(ANT_DET) of the interface connector.
The following table shows the ATS97 parameters.
 Example
// Connect the antenna
ATS97?
001
ATS97
OK
ATS97=?
ERROR
// Disconnect the antenna
ATS97?
000
+MRST, Perform Hard Reset
The +MRST command enables customer software to perform a hard reset to the G24-L unit.
Command Type
Syntax
Response/Action
Remarks
Execute
ATS97
OK
or:
+CME ERROR: <err>
Read
ATS97?
<info>
OK
or:
+CME ERROR: <err>
The Read command indicates whether 
the antenna is connected.
Table 3-94: ATS97 Parameters
<Parameter>
Description
<info>
000
The antenna is not connected
001
The antenna is connected
Command Type
Syntax
Response/Action
Remarks
Set
+MRST
OK
The Set command performs a graceful 
hard reset to the G24-L module.
Note:
The Read and Test commands 
are not permitted for the 
+MRST command.