PioneerPOS G24-LC 用户手册

下载
页码 444
Chapter 3:  AT Commands Reference
 April 15, 2008
G24-L AT Commands Reference Manual
3-171
OK
AT+MADIGITAL=0 
OK
AT+MADIGITAL? 
+MADIGITAL: 0
OK
AT+MADIGITAL=3 
ERROR
AT+MADIGITAL? 
+MADIGITAL: 0
OK
+CALM, Alert Sound Mode
This command handles the selection of the G24-L's alert sound mode. The value of the command 
is saved after a power cycle.
The following table shows the +CALM parameters.
Note:
Selecting the ring mode with this command retrieves the current alert volume level 
setting.
Example
AT+CALM=?
+CALM: (0,1)
OK
AT+CALM?
+CALM: 0
OK
AT+CALM=1
OK
Command Type
Syntax
Response/Action
Remarks
Set
+CALM=<mode>
OK
+CME ERROR: <err>
The Set command sets the alert sound 
mode.
Read
+CALM?
+CALM: <mode>
+CME ERROR: <err>
The Read command displays the 
current alert sound mode setting.
Test
+CALM=?
+CALM: (list of 
supported <mode>s)
+CME ERROR: <err>
The Test command displays the list of 
supported modes.
Table 3-113: +CALM Parameters
<Parameter>
Description
<mode>
Alert sound mode of the G24-L.
0
Ring (default)
1
Silent mode (ring prevented)