National Instruments 370551A-01 用户手册

下载
页码 139
Chapter 6
NI-VXI Configuration Utility
© National Instruments Corporation
6-11
Figure 6-5 shows the Device Configuration Editor. The following 
paragraphs describe the options you can select for each of the fields.
Figure 6-5.  PCI-MXI-2 Device Configuration
Default Controller (LA –1)
Many NI-VXI functions use controller as a parameter with –1 accepted as 
a valid value. You use this selection to determine which controller you are 
referring to when you use –1 in these NI-VXI functions. Review the 
descriptions of the NI-VXI functions to determine which are applicable for 
this control.
By default, the Default Controller (LA –1) option is set to First remote 
controller
, so that any NI-VXI functions that are passed the value of –1 for 
the controller parameter will be executed on the first VXI/VME-MXI-2 in 
the MXI-2 chain. If you select the Local controller option, the NI-VXI 
functions execute on the PCI-MXI-2.