National Instruments 370551A-01 用户手册

下载
页码 139
Chapter 6
NI-VXI Configuration Utility
© National Instruments Corporation
6-15
You can select the Yes or No options to manually determine whether the 
PCI-MXI-2 should be the MXIbus System Controller. You must still be 
certain to cable the MXIbus system appropriately when you make either of 
these selections.
Note
Make sure the MXI-2 cable is connected to the PCI-MXI-2 when you power on or 
reboot the computer. This is required for the PCI-MXI-2 to automatically detect whether it 
will be the MXIbus System Controller.
MXI Bus Timeout
The MXIbus Bus Timeout (BTO) is a watchdog timer for transfers on the 
MXIbus. The MXIbus BTO operates only when the PCI-MXI-2 is acting 
as the MXIbus System Controller.
After the specified amount of time has elapsed, the BTO circuitry 
terminates a MXIbus cycle if no slave has responded. The BTO is also 
disabled when the current MXIbus cycle maps to the VXI/VMEbus through 
a VXI/VME-MXI-2.
The default timeout value is 1 ms. If the Enable MXI-2 Auto Retry 
checkbox option is enabled, you should use a MXI Bus Timeout of 1 ms 
or greater.
MXI CLK10
The PCI-MXI-2 is capable of either receiving or driving the MXIbus 
CLK10 signal.
You can use the Drive or Receive options of the MXI CLK10 feature to 
control the direction of the MXIbus CLK10 signal. By default all MXI-2 
boards receive MXI CLK10 (the Receive option is active); therefore, you 
must choose one board on your MXI-2 bus to drive CLK10 by changing the 
value of the control to Drive. For most configurations, it is recommended 
to choose the System Controller as the CLK10 source for simplicity. 
The only exception you may want to make is if you want your triggers 
synchronous to the VXI 10 MHz clock.
Caution
Do not configure more than one MXIbus device to drive MXIbus CLK10. Having 