NI-VXI Configuration Utility
© National Instruments Corporation
6-27
Arbiter Timeout
An arbitration timeout feature is available on the VXI/VME-MXI-2 when 
it is acting as the VMEbus arbiter. This feature applies only to a VXI Slot 0 
(VMEbus System Controller) VXI/VME-MXI-2. By default, this option is 
enabled.
The timer begins when the arbiter circuit on the VXI/VME-MXI-2 drives 
one of the BGOUT lines on the backplane. If no device takes over the bus 
within the timeout limit, the BGOUT is removed and the bus is either idle 
or granted to another requester.
MXI Bus Options
Use the options in this group to control features of the MXIbus interface on 
the VXI/VME-MXI-2 module.
MXI Bus System Controller
You can use the System Controller control to determine whether the 
VXI/VME-MXI-2 acts as the MXI Bus System Controller. When the Auto 
setting (the default setting) is active, the VXI/VME-MXI-2 automatically 
can sense from the MXIbus cable whether it should be the controller.
You can select either Yes or No to manually determine if the 
VXI/VME-MXI-2 should be the MXI Bus System Controller. You must 
still be certain to cable the MXIbus system appropriately when you make 
either of these selections. 
MXI Bus Timeout Value
The MXI Bus Timeout (BTO) is a watchdog timer for transfers on 
the MXIbus. The MXIbus BTO unit operates only when the 
VXI/VME-MXI-2 is acting as the MXI Bus System Controller. The 
functionality of this control is similar to that of the VXI Bus Timeout 
control described in th
 section. The options range 
from 8
µs to 128 ms, with a default value of 1 ms. 
After the specified amount of time has elapsed, the BTO circuitry 
terminates a MXIbus cycle if no slave has responded. The BTO circuitry is 
automatically deactivated when the VXI/VME-MXI-2 is not acting as the 
MXI Bus System Controller. The BTO is also disabled when the current 
MXIbus cycle maps to the VXI/VMEbus through a VXI/VME-MXI-2.