NEC NDA-30115-001 用户手册

下载
页码 116
Page 74
NDA-30115  Revision 1.0
Message Formats
Property Management System - Communication Interface
Room Image Set 2
Figure 4-48   Room Image Set 2
The message fields are:
FC -- Function Codes that use this message format are: (FTC-FC)
17-5 -- Room Image Set 2 (Normal Request from PMS)
17-6 -- Room Image Set 2 (Normal Answer from NEAX)
17-7 -- Room Image Set 2 (Recovery Request from PMS)
17-8 -- Room Image Set 2 (Recovery Answer from NEAX)
Extension -- Extension number. If the extension number is less than six digits, 
left justify the number and fill the remaining bytes with space (20H) characters.
Vacancy -- Vacancy/Occupancy flag. The possible values are:
0 -- Vacant.
1 -- Occupied.
Status - Message Waiting status. The possible values are:
0 -- Message Waiting Lamp is off.
1 -- Message Waiting Lamp is on.
Code -- Restriction code for this extension. The possible codes are:
0 -- Do Not Disturb and Room Cut-Off are cancelled.
1 -- Room Cut-Off is set, Do Not Disturb is cancelled.
5 -- Do Not Disturb is set, Room Cut-Off is cancelled.
6 -- Do Not Disturb and Room Cut-Off are set.
Vacancy
Stay
Reserve
Language
Cleaning
Wake Up
Wake Up
** Multiple Function Codes use this message. See below.
Status
Result
Status
Time
‘1’ ‘7’
‘2’
‘3’
**
Extension
0
1
2
3
4
6
8
9
15
16
STX
SA
UA
EI
FTC
MSC
FC
6
1
1
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
1
1
1
1
1
17
18
19
20
21
Code
22
23
27
28
1
4