Preparing for installation
201i Server Hardware Installation
45
Meridian 1 I/O panel connections
On large Meridian 1 systems (such as Option 51C), the 201i server requires 
two connections from the slots to the I/O panel on the rear of the switch, as 
follows:
„
One connection is for the multi I/O cable.
This connection corresponds to the left slot (when viewing the front of 
the Meridian 1 switch).
„
The other connection is for the external SCSI device.
This connection corresponds to the right slot (when viewing the front of 
the Meridian 1 switch).
For information about slot and rear bulkhead wiring, refer to the Meridian 1 
System Installation and Maintenance Guide
 (NTP 553-3001-210).
CLAN and ELAN network requirements
If you have a LAN (for example, customer LAN [CLAN] or embedded 
LAN [ELAN]), the LAN must be configured and the appropriate 
networking equipment must be available.
Succession 1000
A pair of consecutive slots in any Media Gateway or 
Media Gateway Expansion.
Note: The 201i server cannot be installed in slots 0 or 
4, because these slots are dedicated to other cards. 
For more information about cards and slots, refer to 
the Succession 1000 Planning and Installation Guide 
(NTP 553-3023-210).
Switch
Slots