Chapter 9 Customizing the portal and user logon 415
Nortel Secure Network Access Switch 4050 User Guide
 
The Link menu includes the following options:
/cfg/domain 1/linkset <linkset ID>/link <index>
followed by:
move <new index>
Moves the link to a new position in the linkset. The 
index numbers of existing link entries with this index 
number and higher are incremented by 1.
new index
 is an integer in the range 1 to 256 
that indicates the position of the link in the linkset
For example: You have two portal links, Link 1 and 
Link 2. To move Link 2 so it displays before Link 1 on 
the portal page, enter the following command:
>> Link 3# move 1
Link 2 becomes Link 1, and Link 1 becomes Link 2.
text <text>
Specifies text to display as the clickable link text on the 
portal Home tab.
text
 is an ordinary text string or HTML code
Provide descriptive text that clearly identifies the 
targeted resource. The client sees only the link text, not 
the URL contained in the link.
type external|ftp
Specifies the type of link. The options are:
external
 — directs the client to a web page. The 
external link is not secured by the Nortel 
SNAS 4050.
ftp
 — directs the client to a directory on an FTP 
file exchange server
The default is 
external
.
The Link menu changes to include a command 
corresponding to the specified link type.
Note: Nortel Secure Network Access Switch 
Software Release 1.0 supports 
external
 links only.
external
Accesses the External Settings menu, in order to 
configure settings for the link (see 
This command displays only if the link type is 
external
.
ftp
Accesses the FTP Settings menu, in order to configure 
settings for the link (see 
). 
This command displays only if the link type is 
ftp
.
del
Removes the link from the current configuration.