Nortel Networks 4050 用户手册
Appendix B Syslog messages 867
Nortel Secure Network Access Switch 4050 User Guide
copy_software_release_failed
ALARM
(CRITICAL)
(CRITICAL)
System
Control
Control
A Nortel SNAS 4050 failed to install a
software release while trying to install the
same version as all other Nortel
SNAS 4050 devices in the cluster. The
failing Nortel SNAS 4050 tries to catch up
with the other cluster members as it was
not up and running when the new software
version was installed.
software release while trying to install the
same version as all other Nortel
SNAS 4050 devices in the cluster. The
failing Nortel SNAS 4050 tries to catch up
with the other cluster members as it was
not up and running when the new software
version was installed.
css error: <reason>
ERROR
Traffic
Processing
Processing
Problem encountered when parsing an
style sheet. It may be a problem with the
css parser in the Nortel SNAS 4050 or it
could be a problem on the processed page.
style sheet. It may be a problem with the
css parser in the Nortel SNAS 4050 or it
could be a problem on the processed page.
DNS alarm: all dns servers are
DOWN
DOWN
CRITICAL
Traffic
Processing
Processing
All DNS servers are down. The Nortel
SNAS 4050 cannot perform any DNS
lookups.
SNAS 4050 cannot perform any DNS
lookups.
DNS alarm: dns server(s) are UP
INFO
Traffic
Processing
Processing
At least one DNS server is now up.
Domain:1, Switch: <switchID>
ERROR cmd timeout for cmd
:<commandID>
ERROR cmd timeout for cmd
:<commandID>
ERROR
NSNAS
An internal command between the
specified switch and the Nortel SNAS 4050
timed out. Check connectivity between the
switch and the Nortel SNAS 4050.
specified switch and the Nortel SNAS 4050
timed out. Check connectivity between the
switch and the Nortel SNAS 4050.
failed to locate corresponding
portal for portal authenticated http
server
portal for portal authenticated http
server
ERROR
Traffic
Processing
Processing
Portal authentication has been configured
for an http server, but no portal using the
same xnet domain can be found. Make
sure that there is a portal running using the
same xnet id.
for an http server, but no portal using the
same xnet domain can be found. Make
sure that there is a portal running using the
same xnet id.
Failed to log to CLI :<reason> --
disabling CLI log
disabling CLI log
ERROR
Traffic
Processing
Processing
Failed to send troubleshooting log to CLI.
Disabling CLI troubleshooting log.
Disabling CLI troubleshooting log.
failed to parse Set-Cookie
<header>
<header>
ERROR
Traffic
Processing
Processing
The Nortel SNAS 4050 got a malformed
Set-Cookie header from the backend web
server.
Set-Cookie header from the backend web
server.
Failed to syslog traffic :<reason>
-- disabling traf log
-- disabling traf log
ERROR
Traffic
Processing
Processing
Problem occurred when the Nortel
SNAS 4050 tried to send traffic logging
syslog messages. Traffic syslogging was
disabled as a result.
SNAS 4050 tried to send traffic logging
syslog messages. Traffic syslogging was
disabled as a result.
Failed to write to config filesystem EMERG
OS
Probable hardware error. Reinstall.
Found <size> meg of phys mem
INFO
Start-up
Amount of physical memory found on
system.
system.
gzip error: <reason>
INFO
Traffic
Processing
Processing
Problem encountered when processing
compressed content.
compressed content.
Table 204
Syslog messages in alphabetical order (Sheet 3 of 10)
Message
Severity
Type
Explanation