Finisar FTLX1461E2 用户手册

下载
页码 10
FTLX1461E2 Product Specification – October 2008
   
 
 
 
© Finisar Corporation – October 2008  
Rev B 
 
Page 3 
Receive Functions 
Reserved 
Reserved 
 O 
38 
39 
Reserved For Future Use 
Reserved For Future Use 
RX LANE 0+ 
RX LANE 0– 

41 
42 
Module XAUI Output Lane 0+ 
Module XAUI Output Lane 0– 
RX LANE 1+ 
RX LANE 1– 

44 
45 
Module XAUI Output Lane 1+ 
Module XAUI Output Lane 1– 
RX LANE 2+ 
RX LANE 2– 

47 
48 
Module XAUI Output Lane 2+ 
Module XAUI Output Lane 2– 
RX LANE 3+ 
RX LANE 3– 
AC-coupled, 
Internally biased 
differential 
XAUI 

50 
51 
Module XAUI Output Lane 3+ 
Module XAUI Output Lane 3– 
DC Power 
GND 
0 V DC 
 
1, 2, 3, 33, 34, 
35, 36, 37, 40, 
43, 46, 49, 52, 
53, 54, 57, 60, 
63, 66, 69, 70 
Ground connection for signal ground 
on the module 
APS 
+1.2 V 
 
7, 8, 28, 29 
Input from Adaptive Power Supply 
APS SENSE 
+1.2 V 
 
27 
APS Sense Output. Connected to the 
APS input inside transponder. 
APS SET 
 
 
25 
Feedback input from APS. 
Connected to GND through a 1180Ω 
resistor inside the transponder. 
3.3 V 
+3.3 V DC 
 
5, 6, 30, 31 
DC Power Input, +3.3 V DC, 
Nominal 
5.0 V 
+5.0 V DC 
 
4, 32 
DC Power Input, +5.0 V DC, 
Nominal 
Reserved 
 
 
26 
Reserved for APD. 
Reserved  
  13 
Reserved.