Nxp Semiconductors UM10237 用户手册
![Nxp Semiconductors](https://files.manualsbrain.com/attachments/fccaa96c7791e96162626b2f8f54b82bf96e15b2/common/fit/150/50/deab3bab3bb4be851ec901ed1b8a87b96e9414e9dda8a447d23580407a5f/brand_logo.gif)
UM10237_2
© NXP B.V. 2008. All rights reserved.
User manual
Rev. 02 — 19 December 2008
589 of 792
NXP Semiconductors
UM10237
Chapter 22: LPC24XX I
2
C interfaces I
2
C0/1/2
If the AA bit is reset during a transfer, the I
2
C block will return a not acknowledge (logic 1)
to SDA after the next received data byte. While AA is reset, the I
2
C block does not
respond to its own slave address or a general call address. However, the I
2
C bus is still
monitored and address recognition may be resumed at any time by setting AA. This
means that the AA bit may be used to temporarily isolate the I
means that the AA bit may be used to temporarily isolate the I
2
C block from the I
2
C bus.