Finisar FTLF1217P2XTL 用户手册

下载
页码 13
FTLF1217P2xTL Pluggable SFP Product Specification – September 2008 
 
 
 
© Finisar Corporation September 13, 2008 Rev. B   
Page 2 
I. 
Pin Descriptions  
 
Pin Symbol 
Name/Description 
Ref. 
1 V
EET
Transmitter Ground  (Common with Receiver Ground) 
2 T
FAULT
Transmitter Fault.  
3 T
DIS
Transmitter Disable. LED output disabled on high or open. 
MOD_DEF(2) 
Module Definition 2. Data line for Serial ID. 
MOD_DEF(1) 
Module Definition 1. Clock line for Serial ID. 
MOD_DEF(0) 
Module Definition 0. Grounded within the module. 
Rate Select 
No connection required 
 
LOS 
Loss of Signal indication.  Logic 0 indicates normal operation. 
9 V
EER
Receiver Ground  (Common with Transmitter Ground) 
10 V
EER
Receiver Ground  (Common with Transmitter Ground) 
11 V
EER
Receiver Ground  (Common with Transmitter Ground) 
12 RD-
 
Receiver Inverted DATA out.  AC Coupled 
 
13 
RD+ 
Receiver Non-inverted DATA out.  AC Coupled 
 
14 V
EER
Receiver Ground  (Common with Transmitter Ground) 
15 V
CCR
Receiver Power Supply 
 
16 V
CCT
Transmitter Power Supply 
 
17 V
EET
Transmitter Ground  (Common with Receiver Ground) 
18 
TD+ 
Transmitter Non-Inverted DATA in.  AC Coupled. 
 
19 TD-
 
Transmitter Inverted DATA in.  AC Coupled. 
 
20 V
EET
Transmitter Ground  (Common with Receiver Ground) 
 
 
Notes: 
1.  Circuit ground is internally isolated from chassis ground. 
2.  T
FAULT
 is an open collector/drain output, which should be pulled up with a 4.7k – 10k Ohms resistor on 
the host board. Pull up voltage should be between 2.0V to Vcc + 0.3V. A high output indicates an LED 
fault, i.e. LED open or short.  Low indicates normal operation. In the low state, the output is pulled to 
<0.8V. 
3.  LED output disabled on T
DIS
 >2.0V or open, enabled on T
DIS
 <0.8V. 
4.  Should be pulled up with 4.7k – 10kohms on host board to a voltage between 2.0V and 3.6V. 
MOD_DEF(0) pulls line low to indicate module is plugged in. 
5.  LOS is open collector output.  Should be pulled up with 4.7k – 10kohms on host board to a voltage 
between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.