Finisar Surveyor 用户手册

下载
页码 454
7-30
Surveyor 
User’s Guide
Rules of the Capture or Display Filter
There must be at least one IF and one ELSE statement per state. ELSE IF 
statements are optional.
The Post Trigger Buffer Position must be greater than zero and less than 100.
There is always one and only one ROOT statement; you can’t delete the ROOT 
statement.
In the capture filter, setting trigger will always set capture.
For devices other than THGm, Custom Counter 1 is the only counter that can be 
used as a counter condition in a filter template. For THGm, all 7 custom 
counters can be used as a counter condition.
The maximum number of states allowed is four for THGm. 
The number of filters allowed depends on the analyzer-card hardware. A maxi-
mum of 16 total hardware filters are allowed for THGm modules, which can be 
distributed across its four allowed states. Depending on the number of states, the 
micro filters, and the logic combinations used, it is possible to exceed the maxi-
mum number of hardware filters. Contact Finisar customer support if you are 
experiencing problems with writing complex filters that exceed the maximum 
number of hardware filters.