Finisar Surveyor 用户手册

下载
页码 454
8-3
Transmit Specification
Transmit Specifications
8
options available from the dialog box and click on the 
Add
 button. You can also add 
a capture file as a defined stream using the 
Add File…
 button. The added stream 
appears in the 
Defined Streams
 list box. Streams are transmitted by the module in 
the order in which they are defined.
A defined stream may be activated or deactivated by double-clicking on the stream. 
An activated stream has a check mark next to it in the 
Defined Streams
 list box and 
is highlighted with the Windows highlight color; a deactivated stream has no check 
mark and displays in the Windows inactive color. Only activated streams are loaded 
to the module when you click on the 
Load Module
 button. Before loading a module, 
make sure you have activated the streams you want.
Figure 8-1 on page 8-2 shows a synopsis of all streams defined for the Transmit 
Specification. In the example, three streams are defined and only two are activated. 
The stream highlighted in the highlight color set for Windows is the currently 
selected stream. Streams highlighted in the inactive color set for Windows are 
inactive. The settings for the currently selected stream show in the fields of the 
dialog box below the 
Defined Streams
 list box. 
If you modify the values in the current stream and click on 
Add
, a new stream is 
added as the stream after the currently selected stream in the 
Defined Streams
 list 
box. If you modify the values in the current stream and click on 
Modify
, the 
definition of the current stream is changed. 
Radio Buttons and Fields for Defining a Stream
Specify the contents and the size of the stream using the 
DA
SA
Packet Type
Packet Size
, and 
Data
 fields. DA and SA values can be retrieved from the currently 
active name table using the 
Names…
 button. Random or sequential address 
generation is supported by selecting the appropriate radio buttons and using X 
values in the 
DA
 or 
SA
 field. 
Sequence numbers (Start Seq# and Stop Seq#) are used to number the 
packets; packet numbering may be useful at the receiving end. When viewing 
packets at the receiving end, the default location for the two-byte sequence number 
is 32H and 33H. This value can be set in the 
Seq# Offset
 field.
Set the stream mode using the radio buttons and the 
Burst
 check box. The stream 
mode defines the rate at which packets are transmitted from a module and whether 
bursts of packets with a different rate will be transmitted within the stream.
Set the 
Repeat Streams
 field to repeat the stream more than one time. This setting 
specifies the number of times to repeat one complete stream – not how many times 
to repeat transmission of the entire specification, nor the number of bursts within