9-1
Chapter 9
Alarms
Surveyor’s alarms facility enables you to create alarms to automatically monitor 
network resources. Access to Surveyor’s alarms facility is through the 
Resource 
Browser
 docking window located in Surveyor’s main window. The 
Resource 
Browser
 window features a hierarchical directory comprising all hardware devices 
and hosts discovered. 
Right-click on a resource to bring up its alarms. A unique set of alarms exist for 
each analyzer device on the network. 
Alarms are created using an Alarm Editor. The 
Alarm Editor
 window contains tabs 
that group all possible alarms. Each alarm within the alarm table contains default 
threshold values, notification settings, a sampling interval value and an 
Enable/
Disable
 click box. 
Starting a resource automatically activates the alarms associated with that resource. 
You must have Monitor mode set for a resource to have alarms trigger and have 
alarm actions occur.
Actions resulting from alarms are varied and flexible because they are assigned to 
each individual alarm. Whenever an alarm threshold is exceeded, an audible beep 
sounds on the host and an alarm message appears in the 
Message
 window. 
Individual alarms can also be configured to log alarms to a log file, contact 
individuals by e-mail, dial pager numbers, restart the resource, auto save data, stop 
the resource and save data, execute a program, or send an SNMP trap message to a 
management station. 
 Note
Alarms only apply to Surveyor 4.1 or later versions. You cannot create 
alarms if the remote software (
THGs
 image file or Surveyor) is less than 
version 4.1.
!