Thresholds and Alarms
Alarm thresholds are set by specifying the values in the 
Sample Type
Rising Value
Falling Value
, and 
Interval
 fields for each alarm row in the alarm table. The numbers 
or percentages set for rising and falling values are referred to as thresholds. The key 
to creating a meaningful alarm is to specify these values so you get alerted to the 
exact network conditions you want to analyze.
The sample type can be set to either 
Delta
 or 
Absolute
. The setting for the 
Sample 
Type
 field determines how Surveyor will use the threshold values set in the
 Rising 
Value
 and 
Falling Value
 fields. 
An absolute sample means that if the 
Rising Value
 is exceeded an alarm event 
occurs. If a value is specified for the 
Falling Value
, an alarm event occurs when the 
value drops below the threshold. 
A delta sample type means that if a difference between samples increases (rising) or 
decreases (falling) over time is more than the specified threshold, an alarm event 
occurs. The 
Interval
 field sets the time period between samples. Samples are actually 
taken at least twice as often as the interval. This allows the detection of threshold 
crossings that span the sample boundary. For example, if the delta sample is taken 
twice per interval, the sum of the latest two samples are compared to the threshold.
For most cases, the default 
Sample Type
 of delta is more useful. One exception is 
the MAC Layer Alarm for Utilization. Because utilization is expressed in the 
Rising 
Value
 field as a percentage, the absolute sample type is more useful to catch 
utilization that exceeds a certain percentage from a baseline of zero network traffic.
Multi-QoS alarms do not use the 
Sample Type
Rising Value
Falling Value
, and 
Interval
 fields. A simple threshold value is used to trigger the alarm when the 
threshold is exceeded.