Finisar Surveyor 用户手册

下载
页码 454
4-9
Configuring Surveyor
Module Settings (Properties)
4
For THGm modules, the default is no packet slicing (full packet length). For 
THGm, the slicing size must be 64 bytes or greater and packet slicing of 128 bytes 
is not supported for 1Gbps Ethernet. 
For Portable Surveyor 10/100 Ethernet Analyzer Cards, and NDIS cards, the default 
setting is no packet slicing for capture, 128-byte packet slice for monitor. For NDIS 
modules, you cannot have both monitor and capture set to full packet size. 
Stop-and-Save Capture Buffer
Only local devices support a stop-and-save-to-disk function for the capture buffer. 
Check the 
Enable Full Buffer Auto Save
 box to enable the save-to-disk feature. 
When using the save-to-disk feature, capture is stopped when the buffer is full and 
the contents are written to disk. Capture is restarted as soon as the data is written to 
the file. When the capture buffer fills again, the new contents are appended to the 
file. If you start a new capture, the file is overwritten. If capture is stopped before 
the capture buffer contents are full, the buffer contents are not automatically written 
to disk; you must manually save the capture buffer to disk.
Modes
Select the 
Modes
 tab from the 
Configuration
 
 
Module
 
 
Settings...
 to set the 
modes for a module. 
Expert Analysis Mode
Expert Views and Alarms can be disabled. When disabled, no Expert Views or 
Alarms will display in Surveyor software. 
Uncheck the 
Enable Expert Analysis Mode 
box to disable Expert Views and Alarms. 
The default is to enable Expert Analysis. If you do not have the Expert plug-in, you 
cannot enable Expert Analysis Mode.
Non-Well-Known-Ports Mode
Non-well-known port (non-WKP) numbers in tables can be enabled or disabled for 
each module when monitoring with local devices. When disabled, most port num-
bers above 1023 display as TCP Other or UDP Other with no port number pro-
vided. 
It is recommended that you leave this feature disabled unless you are looking for 
specific port numbers greater than 1023, since non-WKP numbers can quickly fill 
Application Layer Tables. Surveyor always displays the port number if the number 
is less than or equal to 1023. Surveyor also displays some ports above 1023 since 
applications associated with them are widely accepted.
Check the 
Monitor TCP/UDP non-well-known-ports individually 
box to enable the 
display of all non-WKP numbers. The default is to not display these port numbers.
With the option enabled all TCP packets with non-WKP numbers (TCP or UDP)