Appendix D
Troubleshooting and SunATM Error Messages
103
The information given to
ifconfig
comes from the
/etc/opt/SUNWconn/atm/
atmconfig
and
/etc/opt/SUNWconn/atm/aarconfig
files. Check the entries
in those files that apply to this interface and verify their contents. For descriptions
of the file formats, see “Editing the atmconfig File” on page 42, and “Editing the
aarconfig File” on page 44, 
or the
atmconfig(4)
and
aarconfig(4)
man
pages.
3. Check the
setup_state
with
aarstat(1M)
.
This command will provide information about the Classical IP status on your
interface. The
setup_state
refers to the completion of the
aarsetup
program.
If the
setup_state
is setup-started, it indicates that the
aarsetup
program has
not completed; it may be delayed by slow switch responses, or failed attempts to
register ATM addresses in
/etc/opt/SUNWconn/atm/aarconfig
. Make sure
that the local address given for your interface in
/etc/opt/SUNWconn/atm/
aarconfig
is unique to this switch. Using
$myaddress
and the reserved server
addresses is a good way to guarantee that all addresses are unique. After making
any changes to
/etc/opt/SUNWconn/atm/aarconfig
, run
aarsetup
again.
If the state is not setup-started or setup-finished, verify that the addresses and
interfaces in
/etc/opt/SUNWconn/atm/aarconfig
are valid, and run
aarsetup
again. If you see any error messages, check their meaning in “Error
4. Verify the
interface_state
in
aarstat(1M)
.
The
interface_state
is either up or down, and reflects the linkstate given in the
output of
qccstat
. If the linkstate is
DL_ACTIVE
, the
interface_state
is up;
otherwise, the
interface_ state
is down. If
aarstat
indicates that the
interface_state
is down, try the suggestions for a linkstate that is not
DL_ACTIVE,
5. Make sure Classical IP is configured correctly.
The
aarstat(1M)
output lists several parameters for Classical IP. The field
arpcsmode
lists whether Classical IP is running as a client, a server, or standalone (a
client with no server configured). Verify that this is correct; if it is not, check your
/
etc/opt/SUNWconn/atm/aarconfig
file entries.
6. If the system is a Classical IP client, verify the server connection.
On systems running in client mode,
aarstat
also provides information about the
server. Verify the server address, and that the
server_state
is connected.
7. If the
server_state
is no-connection or connecting.
The system is likely having a problem establishing a connection to the server. Verify
that the server address is correct, and that there is a system on the network which
has registered that address. The server and applicable switch ports must also be
configured to support UNI signalling, also called Q.2931 or Q.93b.