Appendix D
Troubleshooting and SunATM Error Messages
113
Error Messages From
aarsetup
and
lanesetup
aarsetup: could not become control process
lanesetup: could not become control process
An instance of the setup program was running when another instance was started
up. The second instance exits with this error message. Make sure that there is not
a previous instance of the program still running. The setup program might take a
while to complete if the switch is slow to respond.
aarsetup: could not open stream to Q93B
lanesetup: could not open stream to Q93B
The program was unable to communicate with the Q93B driver. Make sure that
you run
aarsetup
or
lanesetup
as root, and that the SUNWatm package has
been properly installed.
aarsetup: could not scan input file
lanesetup: could not scan input file
The program was unable to open the
/etc/opt/SUNWconn/atm/aarconfig
or
/etc/opt/SUNWconn/atm/laneconfig
file (or the file specified on the
command line). Verify that the appropriate file exists, and has the proper
permissions. Also make sure you run
aarsetup
or
lanesetup
as root.
aarsetup: exiting because of errors
lanesetup: exiting because of errors
Errors were encountered while parsing the
/etc/opt/SUNWconn/atm/
aarconfig
or
/etc/opt/SUNWconn/atm/laneconfig
file, so the setup
program cannot successfully complete. Correct the error condition and then
execute either
aarsetup
or
lanesetup
.
aarsetup: <interface> running as a server, but PVC-only ‘t’
entries exist
The
aarsetup
program has found an entry in
/etc/opt/SUNWconn/atm/
aarconfig
, meaning that this interface will be running as a server; however,
there are table entries (entries) containing only PVCs, which cannot be entered
into the server’s ATM ARP table. Verify your interface’s status (server, client, or
stand-alone), make sure all entries include ATM addresses, and execute
aarsetup