Maretron NBE100 用户手册

下载
页码 14
 
NBE100 User's Manual  
 
 
 
 
Page 6 
 
 
Revision 1.0 
2.5.2  Device Label 
Program this parameter with a text string which identifies this particular NBE100, to allow you 
to easily distinguish it from other NBE100’s on the network. 
 
2.5.3  Advanced Configuration… 
Certain parameters do not normally need to be set in order for normal operation, but are 
included in an advanced configuration section for use in special situations. 
 
2.5.3.1  Restore Factory Defaults 
Selecting this configuration option causes all stored parameters in the NBE100 to be reset to 
the values they contained when the unit was manufactured. 
 
3  Maintenance 
Regular maintenance is important to ensure continued proper operation of the Maretron 
NBE100.  Perform the following tasks periodically: 
 
•  Clean the unit with a soft cloth.  Do not use chemical cleaners as they may remove 
paint or markings or may corrode the NBE100 enclosure or seals. Do not use any 
cleaners containing acetone, as they will deteriorate the plastic enclosure. 
•  Ensure that the unit is mounted securely and cannot be moved relative to the mounting 
surface.  If the unit is loose, tighten the mounting screws.  
•  Check the security of the cables connected to the NMEA 2000
®
 connector, and tighten if 
necessary. 
 
4  Troubleshooting 
If you notice unexpected operation of the Maretron NBE100, follow the troubleshooting 
procedures in this section to remedy simple problems. If these steps do not solve your 
problem, please contact Maretron Technical Support (refer to Section 6 for contact 
information). 
 
Symptom 
Troubleshooting Procedure 
No devices on one side 
of the NBE100 are 
visible from a display 
connected to the other 
side. 
•  Ensure that the NBE100 is properly connected to the NMEA 
2000
®
 network segments. 
•  Ensure that both NMEA 2000 network segments have 
power. 
•  Ensure that both NMEA 2000 network segments have two 
termination resistors fitted.