Encore electronic Z8ENCORE000ZCO 用户手册
Z8 Encore!
®
Flash Microcontroller Development Kit
User Manual
24
UM014605-0208
Z8 Encore!® Evaluation Board
through
list jumper information concerning the shunt
status, functions, and devices affected of selected jumpers.
J11
SocketModem Power
(3 V DC/5 V DC)
(3 V DC/5 V DC)
J12
RS-485_1_EN
J13
RS-485_2_EN
J14
RT_1
J15
RT_2
Table 8. J6.9–J6.11-Modem Enable/Disable
Shunt Status Function
Device Affected
IN
Modem connector (P2) is
disabled
disabled
UART1 cannot communicate through P2.
Ports D and F can be assigned to functions
other than UART1.
Ports D and F can be assigned to functions
other than UART1.
OUT
Modem connector (P2) is
enabled
enabled
If the embedded SocketModem is not in the
socket, UART1 communicates through P2.
socket, UART1 communicates through P2.
Table 9. J6.12–J6.14-Console Enable/Disable
Shunt
Status
Status
Function
Device Affected
IN
Console connector (P1) is disabled If J6.12–14 is IN and J10 is IN, Port A
(3-5) is assigned to IrDA; if J10 is
OUT Port A (3-5) is assigned to
UART0.
OUT Port A (3-5) is assigned to
UART0.
OUT
Console connector (P1) is enabled None
Table 7. Configuration Headers and Jumpers (Continued)
Header
Function
Related Headers,
Registers or Devices
Registers or Devices