Promise Technology TX2200 用户手册

下载
页码 128
Chapter 5: WebPAM
57
Controller Settings
Click on the Settings tab to access controller settings.
Rates – Allocates system resources between the background process (such 
as Rebuild, Media Patrol, Expansion/Migration, Initialization and 
Synchronization) and the data read/write activity.
High setting assigns most of the system resources to background 
processes. The process will finished sooner but read/write requests are 
handled slower.
Medium setting tries to balance system resources between the 
background processes and data input/output activity. 
Low setting assigns most of the system resources to handling read/write 
requests. Read/write requests are handled at nearly normal speed while the 
background processes take longer.
Automatic Rebuild Status – When enabled, a critical or degraded logical 
drive will rebuild itself automatically after you replace the failed disk drive. 
Automatic Rebuilding applies to RAID 1 logical drives only.
Buzzer – When enabled, the FastTrak controller’s buzzer will sound to 
report a problem.
S.M.A.R.T. Status – SMART, an acronym for Self-Monitoring Analysis and 
Reporting Technology, is a feature of the disk drive software. When enabled, 
the FastTrak controller polls the disk drives for SMART information and 
reports it to you.
S.M.A.R.T. Check Polling Interval – The FastTrak controller periodically 
polls the physical drives for SMART information and displays it in WebPAM.