Promise Technology TX2200 用户手册

下载
页码 128
Chapter 5: WebPAM
83
3.
Click on the Synchronization tab in Management View.
4.
Click on the Disable option.
Logical Drive Initialization
When logical drive is first created, you can select one of three choices for 
initialization:
Quick Initialization – Erases the reserve and master boot sectors of the 
physical drives being added to the logical drive. 
Full Initialization – Erases all sectors of the physical drives being added to 
the logical drive. 
None – No initialization. This choice is not recommended. 
When you select full initialization, the process takes some time, depending on the 
size of the physical drives selected for the logical drive. The Initialization tab 
enables you to pause the initialization process so that more of FastTrak's 
resources are available for other operations. When the other operations are 
done, you can resume the initialization of your new logical drive.
1.
Click on the Logical Drive View 
 icon in Tree View. 
2.
Click on the Logical Drive 
 icon of the logical drive whose initialization you 
want to pause. 
3.
Click on the Initialization tab in Management View. 
4.
Click the Pause button.
The initialization process stops. 
5.
Click the Resume button.
The initialization resumes from the point where you paused it. 
Logical Drive Activation
This feature enables you to convert a RAID 1 logical drive from offline to critical 
status, so you can rebuild the logical drive and access your data. This condition 
occurs when a single physical (disk) drive from a RAID 1 logical drive is 
connected to the FastTrak Controller card.
Note the this feature does not apply to an offline RAID 0 logical drive.
In the example below, icons of a white X within a red circle appear over the 
FastTrak, Controller, Logical Drive View, and Logical Drive icons. In 
Management View, the status is shown as Offline.
The image below was narrowed to fit on the page.