Note: Stacking units do not have their own databases and configurations settings, and likewise, 
do not have their own network addresses. You cannot configure one using the front panel 
controls on UMT S units. 
9.  Reset Unit (Paragon II Unit Switch): Enables restart of Paragon II unit as if unit’s power had 
been physically turned off and back on again.  
  
With Paragon II unit firmware 2B1 and User Station (UST1) firmware 2K10 or higher, either 
a power reset or a factory “function” reset can be performed from the front panel of the 
Paragon II unit using shortcut button combinations. 
 
Power Reset: 
Hold the Ç and È buttons on the front panel of the Paragon II unit simultaneously for 
approximately three seconds. When the front panel stops scrolling, release the buttons. 
 
Factory “Function” Reset: 
Hold the Ç and È buttons on the front panel of the Paragon II unit simultaneously while pressing 
the  FUNC button. When the front panel stops scrolling, release the Ç and È buttons, wait an 
additional three seconds, then release the FUNC button. 
When “Clear Database Hit Ent/ESC?” appears on the LCD, press the ESC button if you want to 
exit the screen without clearing the database. To clear the database, press the ENT button; “Clear 
All?” appears on the LCD.  If you press the ESC button once more, the channel configuration 
will be cleared and will be rebuilt later by the UMT. This is called a Partial Reset.  However, if 
you press the ENT button, both the channel configuration and the user profile and system settings 
will be cleared.