Guidelines for System Configuration 
•  Only one user should attempt to modify/update the System Administration Menu at one time 
(especially the User Configuration and Channel Configuration options). 
•  Z-CIMs should be added one at a time to a Z-CIM chain. The Administrator should read from 
message banner that the database has been completely updated before adding a new Z-CIM. 
•  If updating the system is necessary at Installation, make certain all users have logged off.  
•  When powering ON existing stable configurations (i.e., if you are NOT replacing or adding 
switches and NOT swapping the order of switches) or when you are Power Cycling a 
cascaded configuration, Raritan recommends that you 1) Power ON the third tier switches (if 
a third tier exists), then 2) Power ON the second tier switches, and 3) Power ON the Paragon 
II base unit. User Stations can be powered ON and OFF at any time as needed. Please note 
that this order is the reverse of upgrading a cascaded configuration: when upgrading, first 1) 
Power ON  the base tier, then 2) Power ON the second tier, and 3) Power ON the third tier (if 
a third tier exists).   For  configurations  where switches are added, replaced, or swapped (in 
order), we recommend Powering ON starting from the third tier, moving to the second, tier, 
and then the base tier, and in addition, performing a partial reset of the database. 
•  When naming or renaming a CIM, switch to that CIM to activate it and to ensure the new 
name is stored or updated in the UMT database.  
 
System Configuration 
To set certain global parameters, select option 1, System Configuration, from the Administration 
Menu and press ENTER.  
1.  Press the down-arrow or TAB key to move the highlight forward, or the up-arrow or SHIFT 
TAB to move the highlight backward to a desired field. Press ENTER to edit the field. The 
highlighted area will turn green. Some fields have character or numeric values you can type 
in; others have values you can toggle between with the arrow keys. When editing is complete, 
either press ENTER followed by S to save your changes, or press ESC to abort the changes 
and continue using the previous settings. 
 
Figure 41 System Configuration Menu for P2-EUST  
•  Device ID: Type in the desired name for the single or master Paragon II Base Unit. It is 
important for Base Units in a cascaded system with multiple Base Units to have distinctive 
names, so that users can tell them apart. (The system will assign each Base Unit the default 
name “Paragon usersxchannel ports”: each P2-UMT242 will be named “Paragon 242, each 
P2-UMT442 “Paragon 442,” etc.)