Riverstone Networks OAW-AP60 用户手册

下载
页码 20
18 Alcatel-Lucent  |  OmniAccess AP
Environmental Requirements
OAW-AP41, AP60,   AP61, AP65 AND 
OAW-AP70 
Temperature
• Operating: 0 to 50º C (32 to 122º F)
• Storage: 0 to 70º C (32 to 158º F)
Humidity 
• 5% to 95% (non-condensing)
OAW-AP80
Temperature
• Operating: -30 to 55 ºC (-22 to 131 ºF)
• Storage: -40 to 80 ºC (-40 to 176 ºF)
Humidity 
• 0% - 95% (non-condensing)
Survival Wind  Speed
• 201 Km/hr / 125 mph
Standards
OAW-AP41 AND AP65
• Ethernet IEEE 802.3 / IEEE 802.3u
• Wireless IEEE 802.11a/b/g
• IEEE 802.3af
OAW-AP60 AND AP61 AND  OAW-AP70
• Ethernet IEEE 802.3 / IEEE 802.3u
• Power over Ethernet IEEE 802.3af
• Wireless IEEE 802.11a/b/g
• USB 2.0 (OAW-AP70 only)
OAW-AP80
• Ethernet IEEE 802.3 / IEEE 802.3u
• Wireless IEEE 802.11a/b/g
• PPP over Ethernet RFC2516
Safety 
OAW-AP41
• cULus listed
• IEC 60950 CB certificate and report
• UL Listed (UL60950)
• UL Listed (Canadian Electrical Code/CSA 22.2
No. 60950)
• EN60950 / IEC60950
• EN 60601-1-1 & EN 60601-1-2: (MD
compliance)
OAW-AP60 AND AP61 AND AP70
• CSA/NTRL (CSA 22.2 No. 950 and UL1950)
• EN60950 (TÜV/GS), IEC60950 (CB)
OAW-AP65
• UL Listed (UL60950)
• UL Listed (Canadian Electrical Code/CSA 22.2
No. 60950)
• EN60950 / IEC60950
• UL Listed (UL2043)
• EN 60601-1-2: 2001 (MD compliance
OAW-AP70
• UL Listed (UL60950)
• UL Listed (Canadian Electrical Code/CSA 22.2
No. 60950)
• EN60950 / IEC60950
• National Electrical Code Section 300-22(C)
• Canadian Electrical Code, Part 1, CSA C22.1
Sections 2-128, 12-010(3), and 12-100
• UL2043 plenum rating
OAW-AP80
• cULus listed
• PSE Mark (AC Power Supply)
• IEC 60950 CB certificate and report
• UL Listed (UL60950)
• UL Listed (Canadian Electrical Code/CSA 22.2
No. 60950)
• EN60950 / IEC60950
Electromagnetic Compliance
OAW-AP60 AND AP61 AND AP70 
• FCC Part 15 Class B – OAW-AP70 only
• FCC Part 15 Class A – OAW-AP60 and AP61
• FCC Part 15 Class C 15.207/15.247
• FCC Part 15 Class E 15.407
• ICES- 003 Class A
• RSS 210 (CAN)
• VCCI Class A
• EN 61000-3, EN 61000-4-2, EN 61000-4-3, EN
61000-4-4
• EN 61000-4-5, EN 61000-4-6, EN 61000-4-8,
EN 61000-4-11
• 73/23/EEC and 89/336/EEC
• EN 55022, EN55024 (89/336/EEC)
• ETS 300 328 (89/336/EEC), ETS 301 489
(89/336/EEC)
• AS/NZS 3548 Class A
• RFS 29 (NZ) (OAW-AP70 only)