Renesas M3T-F160-100NRB 用户手册

下载
页码 4
 
(3/4)
 
5. Connection Procedure 
(See Figure 3)
 
 
The procedure for connecting the M3T-F160-100NRB is 
shown below. 
 
(1)  Mount the NQPACK100RB on the user system. 
(2)  Attach the YQPACK100RB on the NQPACK100RB. 
(3) Secure the four corners of the YQPACK100RB with the 
YQ-GUIDE's. 
● Do not use the screws included with the 
YQPACK100RB for fixing the YQPACK100RB. 
● Do NOT use the screwdriver included with the 
NQPACK100RB for fixing the YQ-GUIDE's. That is 
used only for the HQPACK100RB168 or 
HQPACK100RB1622. 
(4) Attach the probe of the emulation pod to the M3T-
F160-100NRB. 
(5)  Connect M3T-F160-100NRB to the emulator probe. 
 
 
YQ-GUIDE -1
YQPACK100RB
NQPACK100RB
100-pin 0.65-mm-pitch
(PRQP0100JB-A, 
formerly 100P6S-A) foot pattern
(5)
(4)
(1)
(2)
(3)
Use a slotted screwdriver.
: No.1 pin
Be sure to align the pins.
M3T-F160-100NRB
FLX160-PRB, 
M3xxxxTx-EPB
or
M3xxxxTx-CPE
Figure 3 Connection procedure of the M3T-F160-100NRB 
 
6. External Dimensions and a Sample Foot Pattern 
 
 
21.8
40
.0
5.
3
16
.5
0.35
0.65
13.8
17.2
19
.8
23
.2
Unit: mm
55.0
●1
M3T-F160-100NRB REV.A
MADE IN JAPAN
IC1
CN1
CN2
30
31
50
51
80
81
100
1a
1b
40a
40b
1a
1b
40a
40b
Figure 4 External dimensions and a sample foot pattern of the M3T-F160-100NRB